M1 - Electric Air Curtains

Implementing this symbol means the business/company has installed an electric air curtain at least on the main entry door. Save $ 3'985.00

A scroll fan, fitted above the main door has the function to prevent loss of heated or cooled air in air-conditioned premises and is mainly installed where there is heavy people traffic. The correct installation is crucial in order to maximize efficiency, the air curtain must overreach the doorframe by at least 50 to 100 mm to avoid wastage of energy. It is also necessary to achieve a correct downwards airflow, adjustable by louvers. Your air-conditioning specialist will be able to advise you and help maximize savings with professional installation. Regular maintenance of the air curtain is required to optimize its functioning and maximize the longevity of the air curtain fan. Most importantly here, is regular cleaning of the air filter, which is generally located under the Air return grill.

SCROLL TABLE

Example: Room/shop 10m x 10m x 2.5m in height well-insulated no additional heat load at closed doors, requires 12 kW Cooling capacity = 4.0 kW/h compressor power consumption. The savings do not include the air-curtain power consumption of an estimated $ 
NoteTimes/Hours/Amount UsedDays Per Week UsedDays Used in One YearConsumption of ResourceTotal Use of ResourceCost of Resource Per UnitTotal Resource Cost in One YearEstimated Implementation CostEstimated Savings in Five YearsEstimate Pay Off Time
Without Implementation20 hrs2454.0 kWh19'600 kW$ 0.27$ 5'292.00---
With Implementation17 hrs245 4.0 kWh16'660 kW$ 0.27$ 4'498.00$ 800.00$ 3'985.00One year